How to Update the PTC-150 Firmware

 



1). Copy P150FPGA.BIN, P150MCPU.BIN & P150MCTL.BIN (3 files total) to a USB FAT formatted drive, 16GB max.

2). Insert the USB drive to the PTC-150's USB port on the rear of the camera

3). press “MENU” in IR remote controller, then select the following options:
[5:SYSYEM > 4:UPDATE SOFTWARE > 5:UPDATE ALL > YES > ENTER]

4). Power down by unplugging the power supply, wait a few seconds, and then plug the unit back in.

5). The update process takes approximately 5 minutes.

The screen will display :
Updated Mot-BD=>OK.
Updated FPGA =>OK.
Updated MCPU =>OK


6). When finished, the OSD will flash"Write-OK" / “Power on again”.

7). Power down by unplugging, wait a few seconds, then plug the unit back in. Once booted, the update is complete and you can remove the USB drive and use your camera.

8). To verify the firmware, go to:
[5:SYSYEM > 4:UPDATE SOFTWARE]

You should see the following versions for firmware version 2.8:
MB CPU: v1.82
MB FPGA: v019
MCTL CPU: v1.00




PLEASE NOTE: Some cameras may take longer than usual to update to version 2.5 or later from version 2.0 or earlier. Most will update within 5-8 minutes and prompt you to restart the camera when completed, but please give this update up to 20 minutes to complete, interrupting this process may require you to send in your camera for service. Once updated you will no longer experience this potential issue.

 

Contact Us

  • Email Us
  • Call Us

    USA

    @ +1 (562) 696-2324

    EU Office

    @ +31 30 261 9656

    UK Office

    @ +44 1457 851000

    Singapore Office

    @ +65 6749 6866

    India Office

    @ +91 120 242 7337

eeb31f9fc244f80caad877e9551752eb@datavideocorporation.desk-mail.com
https://cdn.desk.com/
false
desk
Loading
seconds ago
a minute ago
minutes ago
an hour ago
hours ago
a day ago
days ago
about
false
Invalid characters found
/customer/en/portal/articles/autocomplete