PTC and BC Series Install and Connection Setup Troubleshooting

Last Updated: Jan 16, 2018 02:59PM PST

Datavideo PTC and BC Series
Install and Connection Setup
Troubleshooting


 

SETTINGS TO CHECK

 

  • DIP switches on the bottom of the camera are set to:
  DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8
PTC-150 ON OFF OFF OFF OFF OFF OFF OFF
PTC-150T ON OFF OFF ON OFF OFF OFF OFF
 
  • Cam Address on RMC-180 is set to "81"
     

Please note that our cameras do not use multiple VISCA ID's, because each camera is run straight to the controller instead of in series or daisy chained. So every camera has ID 1, which is reflected in having DIP switch 1 on and 2-3 off, followed by all 4 camera addresses in the RMC-180 menu settings set to 81, which is VISCA ID 1.


INSTALL TIPS
 
  • If using the RMK-150 wall mount, please check behind the mounted cameras to see if any cables are touching the camera head, as this can explain impeded or stuttering pan motions.

     
  • Please make sure that cameras are handled by the bottom base and not the head. Carrying a camera by the head may disrupt the motor's alignment, or damage the mechanical components inside.
  • With the camera powered off, please try gently rotating the head by hand all the way left and right a few times, and test again.

     
  • Avoid mounting cameras close to any HVAC systems as the vibrations can cause image instability, especially when zoomed in.
  • Also avoid mounting cameras to balconies with foot traffic will vibrate, especially when zoomed in, please avoid these positions if possible.

     
  • Please make sure the firmware on the cameras and RMC-180 are up to date.
  • PTC-150 Firmware Update Guide
  • RMC-180 Firmware Update Guide (coming soon, please see manual)

     
  • Once everything is installed and updated, we recommend running the Reset All function in the menu to get the cameras back to factory settings before adjusting them with lighting for their initial setup.

 

CAMERA WILL NOT
POWER ON


Your camera is booting into sleep mode. Simply select the camera on the RMC-180 controller, then go into the RMC menu and select Power, followed by On.

If the camera does not respond, try selecting the camera on your IR remote and press the remote's power button.

If that does not work, make sure the remote is set to the same IR ID as the IR dip switches on the back of the camera near the video outputs


 

  DIP 1 DIP 2 DIP 3 DIP 4
CAM 1 OFF OFF OFF OFF
CAM 2 ON OFF OFF OFF
CAM 3 OFF ON OFF OFF
CAM 4 ON ON OFF OFF

 

Contact Us

  • Email Us
  • Call Us

    USA

    @ +1 (562) 696-2324

    EU Office

    @ +31 30 261 9656

    UK Office

    @ +44 1457 851000

    Singapore Office

    @ +65 6749 6866

    India Office

    @ +91 120 242 7337

eeb31f9fc244f80caad877e9551752eb@datavideocorporation.desk-mail.com
https://cdn.desk.com/
false
desk
Loading
seconds ago
a minute ago
minutes ago
an hour ago
hours ago
a day ago
days ago
about
false
Invalid characters found
/customer/en/portal/articles/autocomplete